Air disinfection machine use management system

1. Carefully follow the relevant provisions of the “Sterilization Machinery Management System”: All purchases of dynamic air sterilizers (hereinafter referred to as sterilizers) must be reported to the Hospital Infection Control Division for approval.

2, the department must have someone responsible for the maintenance and maintenance of the disinfection machine, earnestly study the "user manual" of each disinfection machine, and properly preserved.

3. Before installing, using, and maintaining the sterilizer, the department must read the User's Manual carefully and must master the applicable environment, volume of use, working environment, and maintenance of the product. Those who have not read the "User Manual" in detail shall not operate or use it.

4, disinfection machine is strictly prohibited over-range use, including the applicable environment, applicable volume; if the temperature, humidity, etc. are not within the standard working environment conditions, should change the disinfection method.

5. When using a sterilizer, pay attention to the airtightness of the room. Doors and windows should be closed to reduce the number of indoor personnel as much as possible. It is strictly prohibited for use in flammable and explosive places.

6. The inlet and outlet of the disinfection machine should not have obstructers affecting the air circulation. The “ozone” function is forbidden to open in places where there are people.

7. Pay attention to the surface hygiene of indoor articles to avoid secondary dust. Clean and disinfect the floor, the lower half of the wall and the surface of the indoor objects (including the top of the instrument cabinet) every day; clean and sterilize the entire wall and the ceiling once a month.

8. Check whether the sterilizer is operating properly every day. If any abnormality is found, immediately shut down the power supply and repair it in time. Keep the sterilizer clean and dry. Wet the surface of the sterilizer every week. When it encounters pollution, clean it at any time and record it in detail. When cleaning, pay special attention to the maintenance at the outlet and inlet. The disinfector must not be in direct contact with the water or flushed. The wiper must be turned off when wiped with a damp cloth.

9. Inspect the filter every 3~6 months. If there is a lot of dust, clean it in strict accordance with the “operating instructions” and record it in detail. When it is suspected that the use of the premises is more serious, the inspection frequency should be increased.

10. Check the dust in the machine every 6-12 months. If you need professional assistance, contact the Equipment Division.

11. The equipment department checks and maintains the disinfection machine at least once every six months and has records.

Zhejiang Sujing Purification Equipment Co., Ltd. is located in Daoshui Town, Shangyu District, Shaoxing City, Zhejiang Province. It is an excellent manufacturer in the purification equipment industry in East China. Can provide professional air purification systems for industries such as microelectronics, biomedicine, hospital operating rooms, fiber optic cables, food and beverages, precision instruments, semiconductors, and new material applications in accordance with the ISO14644-1 standard, GB50073-2001 national standard, and national GMP specifications. Engineering design, construction, testing and technical services.
The company's main purification table series, air shower series, fume hood series, biological safety cabinet series are widely used in medical and health, electronics, pharmaceuticals, biology, food, agriculture, forestry, animal husbandry and veterinary, inspection and quarantine, aerospace, automotive manufacturing, Precision instruments, universities and research institutes enjoy a high reputation in the domestic and Southeast Asian markets.
Zhejiang Sujing Purifying Equipment Co., Ltd. is dedicated to serving consumers and distributors all over the world. We will provide you with the best quality products, the most humane services and the lowest price. We sincerely welcome you to join us!

The principle of gas-phase cleaning machine is as follow. When the solvent is heated, the steam forms the gas phase zone. In this area, the oil on the surface of the workpiece is dissolved and washed by steam. When the steam condenses, the dirt along with the grease falls back into the tank to become the cleaning fluid. Then, the cleaning fluid is heated and gasified into steam to clean the workpiece. This continuous cycle ensures the workpiece is always surrounded by the steam of cleaning fluid which overcomes the problem of contaminated cleaning fluid in the past common cleaning process.


The Ultrasonic Gas-phase Cleaning Machine is sealed type with manipulator driving transportation rack, loading by special material baskets, step-type conveying cleaning technology and pneumatic elevator to transport material. Using organic solvent such as trichloroethylene as the cleaning medium to degrease the surface of the workpiece. Then having freeze-drying. The supersonic cleaner is suitable for the cleaning of the Heat Exchanger Parts.


Heat Exchanger Parts Cleaning Machine

Gas-phase Supersonic Cleaning machine, Heat Exchanger Parts Cleaning and Degreasing Equipment, Metal Product Cleaning

Wuxi Better Technology Co., Ltd , https://www.btheatexchanger.com