Ds101X/201X Piston Type Multifunctional Water Pump Control Valve

Model NO.: DS101X/201X
Applicable Temperature: Below 80 Deg C
Flange Standard: Jb/ANSI/DIN/JIS
Test and Inspection Standard: GB/T13927 API598
Application: Outlet of Water Pump
Function: as a Non-Return Valve and Avoid Water Hammer
Trademark: Goole, ODM, OEM
Transport Package: Wooden Case
Specification: CE, SGS
Origin: Wenzhou, Zhejiang, China
HS Code: 8481804090
DS101X/201X Piston Type Multifunctional Water Pump Control Valve
1. Product Introduction
The super hydraulic control valve we made can be divided into Diaphragm type and Piston type. Both are composed by a main valve, a pilot valve, matching tube, fittings and some other components. According to the different working purposes, function and places, only by changing the pipeline assembly of the pilot valve and the fittings to form a complete control system, different valves with different working performances can be resulted.
2. Structure
This valve has the following two types: Diaphragm type and Piston type. Both are  composed by main valve,  regulator, pilot tube, filter, etc.
 
Diaphragm Type
No.
 
Parts Name Material
Diaphragm Type Piston Type
1 1 Body CI / CS / DCI
2,13 2,14 Filter Brass
3 3 Regulator Brass
4 11 Stem S.S
5 8 Diaphragm/Gland NBR / DCI
6 11 Bonnet CI / CS / DCI
7 9 Slow Closing Disc S.S
       
 
Piston Type
No.
 
Parts Name Material
Diaphragm Type Piston Type
8 10 Spring Alloy
9 4 Main Valve Disc DCI
10 12 Seat Brass / S.S
11   Diaphragm Seat CI / CS / DCI
12 13 Regulator Brass
  5 Sleeve S.S
  6 Sleeve Seat CI / CS / DCI
  7 Piston DCI
 
3. Specifications
PN (MPa) Shell Test(MPa) Seat Test (MPa) Minimum Operation Pressure (MPa) Slow Closing Time (S) Applicable Temp. (ºC) Applicable Medium
1.0 1.5 1.0 0.07 3-120 0-80 Water
1.6 2.4 1.6
2.5 3.75 2.5
4.0 6.0 4.4
 
4. Features & Working Performance
 4.1 Features:
  This product is Y Type Structure with Double Chamber Operator. While working, it has following advantages: Half-straight flow direction, Large flowing rate, Low Pressure loss, Steady Open and close, No Pressure Fluctuation, etc. Double Chamber Operation Apparatus can be disassembled as a whole, which is easy for inspection. Diaphragm is made of Nylon Reinforced Rubber, which makes it has long service life. Valve Disc sealing gasket can be removed, which is convenient for maintenance.
 4.2 Working Performance:
  Multifunctional Pump Control Valve can be installed in the system pipelines or the outlet of the pump. While normal working, the inlet side medium push the main valve disc lift, then the medium flows into the middle chamber through the flowing regulator, which makes the valve open quickly. When the valve stop working, the outlet side medium flows into the upper chamber through the regulator, the operator will move downwards and make the main and pilot valve disc move downwards, thus the valve can be closed quickly or slowly and avoid the backwards flowing of the medium.
 
5. Main External Dimension
DN L H D D1 n-d
1.0 MPa 1.6 MPa 2.5 MPa 4.0 MPa 1.0 MPa 1.6 MPa 2.5 MPa 4.0 MPa 1.0 MPa 1.6 MPa 2.5 MPa 4.0 MPa
50 205 270 150 150 150 150 110 110 110 110 4-17.5 4-17.5 4-18 4-18
65 209 270 165 165 165 165 125 125 125 125 4-17.5 4-17.5 4-18 4-18
80 240 340 185 185 185 185 145 145 145 145 4-17.5 4-17.5 4-18 8-18
100 292 400 200 200 200 200 160 160 160 160 4-18 8-18 8-18 8-18
125 330 440 220 220 235 235 180 180 190 190 8-18 8-18 8-22 8-22
150 370 500 285 285 300 300 240 20 250 250 8-23 8-23 8-26 8-26
200 450 640 340 340 360 375 295 295 310 320 8-23 8-23 12-26 12-30
250 500 690 395 405 425 450 350 355 370 385 12-23 12-26 12-30 12-33
300 600 820 455 460 485 515 400 410 430 450 12-23 12-26 16-30 16-33
350 650 950 505 520 555 580 460 470 490 510 16-23 16-26 16-33 2+-36
400 700 1400 565 580 620 660 515 525 550 585 16-26 16-30 16-36 16-39
450 780 1580 615 640 670 685 565 585 600 610 20-26 20-30 20-36 20-39
500 800 1600 670 715 730 755 620 650 660 670 20-26 20-33 20-36 20-42
600 930 1815 780 840 845 890 725 70 770 795 20-30 20-36 20-39 20-48
700 1030 2040 895 910 960   840 840 875   24-30 24-36 24-42  
800 1100 2350 1015 1025 1085   950 950 990   24-34 24-35 24-48  
900 1200 2606 1115 1125 1185   1050 1050 1090   28-34 28-39 28-48  
1000 1300 2765 1230 1255 1320   1160 1170 1210   28-36 28-42 28-56  
 
 
6. Assemble Notification
 6.1 The best assemble direction of the multifunctional pump control valve is horizontal assembling.(i.e. the Bonnet is upwards)
 6.2 Check the medium flowing direction before assembling so as to avoid wrongly assembling.
 6.3 Clean the pipelines before assembling and a strainer needs to be applied in front of the valve, which will avoid the impurity affect the working performance and will prevent the damage of the product.
 6.4 If the working temperature is below 0, heat insulation materials need to be used.
 6.5 There must be enough space to assemble the Multifunctional Pump Control Valve. And the control valve needs to applied behind the check valve. The details can be referenced the assembling drawing.
 
7. Notifications
 7.1 Check the condition of the pilot valve, matching pipes and fittings before operation.
 7.2 Check if the regulator on the pilot valve and matching pipes can work flexibly.
 7.3 Maintain the pipelines after operating the system for some time.
 
8. Testing Methods
 8.1 Open the globe valve 3,12 ( 3, 13 of the Piston type.)
 8.2 Let the pump start working and check if the inlet and outlet pressure is normal.
 8.3 Let the pump stop working and check if there is water hammer and if the pump act reversely.
 8.4 If the water hammer is big, then need to open less of the globe valve.
 8.5 If the pump acts reversely, then need to open more of the globe valve
 
9 Malfunction maintenance
Problem Inspection Item Inspection Methods Maintenance methods
Main valve can't open 1. Pressure is too low Check if the pressure is low Strengthen the pressure
2. Adjusting stem is out   insert the adjusting stem
3. Globe Valve closed   Open the globe valve
4. Pipelines blocked Lower pipelines Remove the blocks
Main valve can't be closed tightly 1. Diaphragm or O-ring is damaged Open the bonnet and take out the damaged diaphragm or piston Change the diaphragm or O-ring
2. Piston is too tight   Downwards the adjusting stem, and then return it when the piston can move flexibly
3 Globe valve closed   Open the globe valve
4. Backwards water pressure is too low Check the water pressure Strengthen the pressure
 
Ms Cathy
Yongjia Goole Valve Co.,Ltd
Heyi Industrial Zone, Oubei, Wenzhou,325105, China
Tel: +86-577-57781015,   Fax: +86-577-67985602
Mob: +86 150 5759 6965,   
 
Web: www.chinavalve1.com

R290 Refrigerant Heat Exchanger

R290 is about 40% of the  filling volume of R134a or R404A. The maximum allowable filling volume of R290 refrigerant is 150g in a single refrigeration cycle system . Properly reducing the inner diameter of the pipeline;Improving the heat efficiency of the condenser,  etc. optimizing the length, spacing and direction  of condenser;Improving the heat transfer efficiency of evaporator, increasing the contact area of the inner wall, and reducing the volume .


R290 Refrigerant Heat Exchanger

R290 Refrigerant Heat Exchanger,R290 All Aluminum Evaporator Coil,R290 Copper Condenser Coil,R290 Aluminum Plate Heat Exchanger