KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct

Model NO.: KCB
Position of Pump Shaft: Vertical Pump
Pump Casing Combined: Verticaljoint Surface Pump
Mounting Height: Suction Centrifugal
Impeller: Closed
Usage: Pump, Pumps, Condensate Pump, Ash Pumps, Circulating Pump
Colour: Costomize
Certificate: ISO9001:2000
Trademark: Lyson
Transport Package: Wooden Sealed Pachaging
Specification: caliber: 20~350mm
Origin: China
HS Code: 8413709990
Model NO.: KCB
Position of Pump Shaft: Vertical Pump
Pump Casing Combined: Verticaljoint Surface Pump
Mounting Height: Suction Centrifugal
Impeller: Closed
Usage: Pump, Pumps, Condensate Pump, Ash Pumps, Circulating Pump
Colour: Costomize
Certificate: ISO9001:2000
Trademark: Lyson
Transport Package: Wooden Sealed Pachaging
Specification: caliber: 20~350mm
Origin: China
HS Code: 8413709990
                                                                       Introduction
KCB gear pump for conveying solid particles and fibers do not contain, non-corrosive, the temperature is not higher than 80 ºC, the viscosity of 5 × 10-6 ~ 1.5 × 10-3m2 / s (5-1500cSt) of lubricating oil or similar Other liquids for lubricating oil.
KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct


KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct
KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct
KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct


                                                                    Features
1, KCB horizontal Multistage gear oil Centrifugal Pump is a vertical structure with a small footprint. The center of gravity of the pump coincides with the center of the pump foot, so it runs smoothly with little vibration and long service life.
2, KCB horizontal Multistage gear oil Centrifugal Pump with the same caliber and the same horizontal center line, without changing the pipeline structure, can be directly installed in any part of the pipeline, the installation is extremely convenient.
3, the motor plus rain cover can be placed directly in the outdoor use, without the need to build pump room, greatly saving capital investment.
4,KCB horizontal Multistage gear oil Centrifugal Pump Head can be changed by changing the pump series (the number of impeller) to meet different requirements, so a wide range of applications.
5, the shaft seal with carbide mechanical seal, reliable seal, no leakage, mechanical loss.
6, energy efficient, beautiful appearance.
7, Note 50 caliber inner casting above forming.
                                   
Conditions of use
1, used to transport clean water or physical and chemical properties similar to clear liquid;
2, the liquid should be transported without solid particles, no fiber, no corrosive, no risk of explosion;
3, the maximum liquid temperature does not exceed 120 ºC;
4, the maximum working pressure does not exceed 2.5MPa;
5, power for 3-phase 380V, 50HZ. Voltage fluctuations within ± 5%;
6, the ambient temperature should be below 40 ºC, relative humidity below 95%.
7,Conveyor containing corrosive media and hot liquid, please put forward when ordering, so that the use of special materials to meet the conditions.
                                     
 Application
KCB gear pump for conveying solid particles and fibers do not contain, non-corrosive, the temperature is not higher than 80 ºC, the viscosity of 5 × 10-6 ~ 1.5 × 10-3m2 / s (5-1500cSt) of lubricating oil or similar Other liquids for lubricating oil.
                                   
Technical Parameters
Q=1.4~192m³/h H=33~230m
n=2900r/min P=1.1~132kw
Dna=25~150mm DNm=25~150mm
temperature range=-15ºC~120ºC Work pressure≤2.5Mpa
                                                                    Installation Instructions
1, the installation of pipe weight should not bear on the pump, or vulnerable ring pump;
2, the pump is the overall structure of the motor, the factory has been factory calibration, so no need to adjust the installation, so the installation is very convenient;
3, before installing the pump should carefully check whether there is any impact on the pump runner pump running hard materials, (such as stones, iron sand, etc.) in case of pump running back loss of flow components;
4, into the installation must be tightened anchor bolts, and each interval in fact, should check the pump during the passage to prevent its loosening, so as to avoid the pump start violent vibration and affect the performance;
5, In order to maintain the convenience and safety, install a regulating valve on the pump inlet and outlet piping and install a pressure gauge near the pump inlet and outlet. For high lift, in order to prevent water hammer, it should also be installed in front of the outlet gate Check valve only to cope with sudden power outages and other lost power accidents, so as to ensure that the pump running in the best conditions, increasing the life of the pump;
6, the pump for a suction occasion, should be equipped with the end of the valve, and the inlet pipe should not have too many corners at the same time there may be leakage, leakage phenomenon, so as not to affect the pump suction performance;

                                                                   Start and stop
Preparation before starting
1, pull the coupling by hand, the impeller should be no card grinding phenomenon, flexible rotation;
2, open the inlet valve, open the exhaust valve so that the liquid filled the entire pump chamber, and then close the exhaust nozzle;
3, such as the delivery of hot liquid, before starting should be preheated, heating rate of 50 ºC / h, the pump is preheated by the continuous circulation of liquid delivery to achieve, so that all parts of the heated uniform;
4, should be manually activated KCB horizontal Multistage gear oil Centrifugal Pump several times so that the lubrication water into the mechanical seal face;
5, move the motor, the steering is correct.
Start and run
1, fully open the inlet valve, close the discharge pipe door;
2, connect the power, when the pump reaches the normal speed, gradually open the valve on the discharge pipe and adjust to the required conditions;
3, observe the instrument readings, check the shaft seal leakage, the normal timing of mechanical seal leakage 3 leakage / min, check the motor, the bearing temperature ≤ 70 ºC, if abnormal, should be promptly addressed.
parking
1, gradually close the discharge pipe valve;
2, close the inlet valve
3, such as the ambient temperature is below 0 ºC. Should drain the pump liquid, so as not to freeze crack pump;
4, such as long-term disabled, the pump should be disassembled clean, packaging and custody.

                                                                Repair and maintenance
In operation, maintenance and care
1, the inlet pipe must be highly sealed, can not leak, leak;
2, KCB horizontal Multistage gear oil Centrifugal Pump are prohibited from long-term operation under cavitation;
3, prohibit the KCB horizontal Multistage gear oil Centrifugal Pump operating in high flow conditions, the motor over-current long-term operation;
4, Regularly check the motor current in the pump operation, try to make the pump run in the design conditions;
5, KCB horizontal Multistage gear oil Centrifugal Pump in operation should be someone care, so as to avoid accidents;
6, KCB horizontal Multistage gear oil Centrifugal Pump for each 500 hours of operation to refuel;
7, KCB horizontal Multistage gear oil Centrifugal Pump after long-term operation, due to mechanical wear and tear, so that the unit noise and vibration increase, parking inspection, the need to change into the vulnerable parts and bearings, unit overhaul period is generally one year.
Mechanical seal maintenance and repair
1, mechanical seal lubricating fluid should be clean without solid particles;
2, mechanical seal is strictly prohibited in the case of dry grinding;
3, KCB horizontal Multistage gear oil Centrifugal Pump (motor) should be activated a few times before starting, so as not to cause a sudden start-up mechanical seal rupture damage.

                                                     Causes of failure and troubleshooting                         
Trouble phenomenon May cause the reason To exclude

1,The pump does not water
 
Inlet valve is not open, out of the pipeline obstruction, Impeller flow blockage
Motor running in the wrong direction, motor phase loss is very slow speed
Suction tube leaks
Pump is not filled with liquid, the pump cavity with air
Inadequate supply of imported water, suction stroke is too high, leakage valve at the end
Pipeline resistance is too large, inappropriate pump selection 
Check, remove obstruction
Adjust the motor steering, tighten the motor wiring
Tighten the sealing surface, remove the air
Open the pump cover or open the exhaust valve and drain the air
Stop checking, adjusting
Reduce the pipe bend, re-select the pump

2, The first pump to check the flow of less than 
 
Pipe, pump runner or impeller blockage, scale deposition ...
Low voltage
Impeller wear
First exclude 1
Remove the obstruction and readjust the valve opening
Regulated
Replace the impeller

3,The power is too large
 
Than the rated flow
Suction stroke is too high
Pump bearing wear

 
Tear to adjust the flow, off the small outlet valve
Lower
Replace the bearing 

 
4, Noise vibration Tube support instability
Liquid mixed with gas
Cavitation produces
Bearing damaged
Motor overloaded to run

 
A solid pipe
Raise suction pressure and exhaust
Reduce the degree of vacuum
Replace the bearing
Adjust by 5
 
 

 
5, The motor heat Flow is too large, overload operation
Partial friction
Motor bearing damaged
Low voltage

 
Off the small outlet valve
Check exclusion
Replace the bearing
Regulated

 
6,Pump leakage Mechanical seal wear
The pump has sand holes or cracks
The sealing surface is not smooth
Loose mounting

 
Screws
Welding repair or replacement
Trimming
Tighten

 
                                                                       Download Google
First,1:multi-stage centrifugal pump product name and model 2:multi-stage centrifugal pump diameter 3:multistage centrifugal pump head (m) 4:multi-stage centrifugal pump motor power (KW) 5: multistage centrifugal pump speed (r / min) Centrifugal pump voltage(V) 6:multistage centrifugal pump suction (m) 7:multistage centrifugal pump with accessories so that we for your correct selection.
Second, if the design unit has selected my company's multi-stage centrifugal pump product model, please press the multi-stage centrifugal pump model directly to the Yangtze River Pump Company Sales Order.
Third, when the use of the occasion is very important or the environment is more complex, please try to provide design drawings and detailed parameters, by our Yangtze River Pumps technical experts for your review checks.
                                                                       Introduction
KCB gear pump for conveying solid particles and fibers do not contain, non-corrosive, the temperature is not higher than 80 ºC, the viscosity of 5 × 10-6 ~ 1.5 × 10-3m2 / s (5-1500cSt) of lubricating oil or similar Other liquids for lubricating oil.
KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct


KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct
KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct
KCB Horizontal Multistage Gear Oil Centrifugal Pump Factory Direct


                                                                    Features
1, KCB horizontal Multistage gear oil Centrifugal Pump is a vertical structure with a small footprint. The center of gravity of the pump coincides with the center of the pump foot, so it runs smoothly with little vibration and long service life.
2, KCB horizontal Multistage gear oil Centrifugal Pump with the same caliber and the same horizontal center line, without changing the pipeline structure, can be directly installed in any part of the pipeline, the installation is extremely convenient.
3, the motor plus rain cover can be placed directly in the outdoor use, without the need to build pump room, greatly saving capital investment.
4,KCB horizontal Multistage gear oil Centrifugal Pump Head can be changed by changing the pump series (the number of impeller) to meet different requirements, so a wide range of applications.
5, the shaft seal with carbide mechanical seal, reliable seal, no leakage, mechanical loss.
6, energy efficient, beautiful appearance.
7, Note 50 caliber inner casting above forming.
                                   
Conditions of use
1, used to transport clean water or physical and chemical properties similar to clear liquid;
2, the liquid should be transported without solid particles, no fiber, no corrosive, no risk of explosion;
3, the maximum liquid temperature does not exceed 120 ºC;
4, the maximum working pressure does not exceed 2.5MPa;
5, power for 3-phase 380V, 50HZ. Voltage fluctuations within ± 5%;
6, the ambient temperature should be below 40 ºC, relative humidity below 95%.
7,Conveyor containing corrosive media and hot liquid, please put forward when ordering, so that the use of special materials to meet the conditions.
                                     
 Application
KCB gear pump for conveying solid particles and fibers do not contain, non-corrosive, the temperature is not higher than 80 ºC, the viscosity of 5 × 10-6 ~ 1.5 × 10-3m2 / s (5-1500cSt) of lubricating oil or similar Other liquids for lubricating oil.
                                   
Technical Parameters
Q=1.4~192m³/h H=33~230m
n=2900r/min P=1.1~132kw
Dna=25~150mm DNm=25~150mm
temperature range=-15ºC~120ºC Work pressure≤2.5Mpa
                                                                    Installation Instructions
1, the installation of pipe weight should not bear on the pump, or vulnerable ring pump;
2, the pump is the overall structure of the motor, the factory has been factory calibration, so no need to adjust the installation, so the installation is very convenient;
3, before installing the pump should carefully check whether there is any impact on the pump runner pump running hard materials, (such as stones, iron sand, etc.) in case of pump running back loss of flow components;
4, into the installation must be tightened anchor bolts, and each interval in fact, should check the pump during the passage to prevent its loosening, so as to avoid the pump start violent vibration and affect the performance;
5, In order to maintain the convenience and safety, install a regulating valve on the pump inlet and outlet piping and install a pressure gauge near the pump inlet and outlet. For high lift, in order to prevent water hammer, it should also be installed in front of the outlet gate Check valve only to cope with sudden power outages and other lost power accidents, so as to ensure that the pump running in the best conditions, increasing the life of the pump;
6, the pump for a suction occasion, should be equipped with the end of the valve, and the inlet pipe should not have too many corners at the same time there may be leakage, leakage phenomenon, so as not to affect the pump suction performance;

                                                                   Start and stop
Preparation before starting
1, pull the coupling by hand, the impeller should be no card grinding phenomenon, flexible rotation;
2, open the inlet valve, open the exhaust valve so that the liquid filled the entire pump chamber, and then close the exhaust nozzle;
3, such as the delivery of hot liquid, before starting should be preheated, heating rate of 50 ºC / h, the pump is preheated by the continuous circulation of liquid delivery to achieve, so that all parts of the heated uniform;
4, should be manually activated KCB horizontal Multistage gear oil Centrifugal Pump several times so that the lubrication water into the mechanical seal face;
5, move the motor, the steering is correct.
Start and run
1, fully open the inlet valve, close the discharge pipe door;
2, connect the power, when the pump reaches the normal speed, gradually open the valve on the discharge pipe and adjust to the required conditions;
3, observe the instrument readings, check the shaft seal leakage, the normal timing of mechanical seal leakage 3 leakage / min, check the motor, the bearing temperature ≤ 70 ºC, if abnormal, should be promptly addressed.
parking
1, gradually close the discharge pipe valve;
2, close the inlet valve
3, such as the ambient temperature is below 0 ºC. Should drain the pump liquid, so as not to freeze crack pump;
4, such as long-term disabled, the pump should be disassembled clean, packaging and custody.

                                                                Repair and maintenance
In operation, maintenance and care
1, the inlet pipe must be highly sealed, can not leak, leak;
2, KCB horizontal Multistage gear oil Centrifugal Pump are prohibited from long-term operation under cavitation;
3, prohibit the KCB horizontal Multistage gear oil Centrifugal Pump operating in high flow conditions, the motor over-current long-term operation;
4, Regularly check the motor current in the pump operation, try to make the pump run in the design conditions;
5, KCB horizontal Multistage gear oil Centrifugal Pump in operation should be someone care, so as to avoid accidents;
6, KCB horizontal Multistage gear oil Centrifugal Pump for each 500 hours of operation to refuel;
7, KCB horizontal Multistage gear oil Centrifugal Pump after long-term operation, due to mechanical wear and tear, so that the unit noise and vibration increase, parking inspection, the need to change into the vulnerable parts and bearings, unit overhaul period is generally one year.
Mechanical seal maintenance and repair
1, mechanical seal lubricating fluid should be clean without solid particles;
2, mechanical seal is strictly prohibited in the case of dry grinding;
3, KCB horizontal Multistage gear oil Centrifugal Pump (motor) should be activated a few times before starting, so as not to cause a sudden start-up mechanical seal rupture damage.

                                                     Causes of failure and troubleshooting                         
Trouble phenomenon May cause the reason To exclude

1,The pump does not water
 
Inlet valve is not open, out of the pipeline obstruction, Impeller flow blockage
Motor running in the wrong direction, motor phase loss is very slow speed
Suction tube leaks
Pump is not filled with liquid, the pump cavity with air
Inadequate supply of imported water, suction stroke is too high, leakage valve at the end
Pipeline resistance is too large, inappropriate pump selection 
Check, remove obstruction
Adjust the motor steering, tighten the motor wiring
Tighten the sealing surface, remove the air
Open the pump cover or open the exhaust valve and drain the air
Stop checking, adjusting
Reduce the pipe bend, re-select the pump

2, The first pump to check the flow of less than 
 
Pipe, pump runner or impeller blockage, scale deposition ...
Low voltage
Impeller wear
First exclude 1
Remove the obstruction and readjust the valve opening
Regulated
Replace the impeller

3,The power is too large
 
Than the rated flow
Suction stroke is too high
Pump bearing wear

 
Tear to adjust the flow, off the small outlet valve
Lower
Replace the bearing 

 
4, Noise vibration Tube support instability
Liquid mixed with gas
Cavitation produces
Bearing damaged
Motor overloaded to run

 
A solid pipe
Raise suction pressure and exhaust
Reduce the degree of vacuum
Replace the bearing
Adjust by 5
 
 

 
5, The motor heat Flow is too large, overload operation
Partial friction
Motor bearing damaged
Low voltage

 
Off the small outlet valve
Check exclusion
Replace the bearing
Regulated

 
6,Pump leakage Mechanical seal wear
The pump has sand holes or cracks
The sealing surface is not smooth
Loose mounting

 
Screws
Welding repair or replacement
Trimming
Tighten

 
                                                                       Download Google
First,1:multi-stage centrifugal pump product name and model 2:multi-stage centrifugal pump diameter 3:multistage centrifugal pump head (m) 4:multi-stage centrifugal pump motor power (KW) 5: multistage centrifugal pump speed (r / min) Centrifugal pump voltage(V) 6:multistage centrifugal pump suction (m) 7:multistage centrifugal pump with accessories so that we for your correct selection.
Second, if the design unit has selected my company's multi-stage centrifugal pump product model, please press the multi-stage centrifugal pump model directly to the Yangtze River Pump Company Sales Order.
Third, when the use of the occasion is very important or the environment is more complex, please try to provide design drawings and detailed parameters, by our Yangtze River Pumps technical experts for your review checks.

38oz Disposable Plastic Rectangular Containers

38Oz Disposable Plastic Rectangular Containers,38Oz Disposable Rectangular Leak-Proof Lunch Box,Pp Material Packing Box 38Oz With Lid,38Oz Rectangular Disposable Lunch Box

Taishan Lvhui Environmental Plastic Technology Co., Ltd. , https://www.cn-lvhui.com