Vertical and Table Type Shaking Incubator with Factory Price

Model NO.: HNY-100D
Control Mode: P.I.D Microcomputer Processing Chip
Cyclotron Frequency Range: 30-600rpm/Min
Pallet Size(mm): 410*360
Volume(L): 70
Power(W): 650
Size(mm): 740*710*510
Trademark: Nanbei
Transport Package: Export Standard Packaging
Specification: CE, ISO 9001, ISO 14001 confirmed
Origin: Zhengzhou, Henan
HS Code: 8479820090
Model NO.: HNY-100D
Control Mode: P.I.D Microcomputer Processing Chip
Cyclotron Frequency Range: 30-600rpm/Min
Pallet Size(mm): 410*360
Volume(L): 70
Power(W): 650
Size(mm): 740*710*510
Trademark: Nanbei
Transport Package: Export Standard Packaging
Specification: CE, ISO 9001, ISO 14001 confirmed
Origin: Zhengzhou, Henan
HS Code: 8479820090

Open type incubated shaker

Features:

1. Well constructed for long term operation.

2. Advance technology ensuring mechanical stability and reliability of operation.

3. Shaking mechanism is constructed with chromium alloy material and high quality cast iron.

4. Circuit breaker protect against excess current, power-off memory to return to original setting, soft start prevents splashing, auto cut-off if motor overheat.

5. Precision microprocessor control system, accuracy of speed ± 1rpm.

6. Brushless high torque motor, maintenance free.

Parameters:

Model

HNY-810

HNY-820

HNY-850

HNY-880

Control mode

P.I.D microcomputer processing chip

Oscillation mode

convolution

Reciprocate

convolution

Reciprocate

Display

LED digital display

Cyclotron frequency range

30-300rpm/min

Cyclotron accuracy

±1

Shake plate shimmy range(mm)

Ø26

 

Max configuration

100ml*22/250ml*12/500ml*8

250ml*92/500ml*66/1000ml*36(double)

 

Standard configuration

250ml*12

250ml*46(double)

Plate size(mm)

430*325

800*600

Plate number

1

2(double)

Size(mm)

456*380*195

900*640*780(double)

Power(w)

80

200

Voltage

AC220±10% 50-60HZ


Vertical double-layer constant temperature shaking incubator

Summary:
This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency
Control feature:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted
Structure feature:
Sort: Microcomputer LCD type

Performance feature:
1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations
3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
4.Overtemperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs.
5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples.
7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.

Parameters:
Model HNY-1102C HNY-2102C HNY-1102 HNY-2102 HNY-1112B HNY-2112B HNY-1112F HNY-2112F
Control mode P.I.D microcomputer processing chip
Convection mode Forced convection
Oscillation mode convolution Reciprocate
Display LCD display
USB data download system Yes
Kudan control system Yes
Cyclotron frequency range 30-300rpm/min 30-280rpm/min
Cyclotron frequency accuracy ±1
Shake plate shimmy range(mm) Ø26 Ø26(Ø35) 0-50
Max configuration 100ml*48/250ml*24/
500ml*24
100ml*90/250ml*56/500ml*48 250ml*90/500ml*74/1000ml*36
Standard configuration 250ml*24 250ml*28
500ml*22
250ml*45
500ml*36
Pallet size(mm) 500*350 745*450 970*560
Timing(h) 0-999
Temp. range(ºC) Ambient temp.+5-60 4-60 Ambient temp.+5-60 4-60 Ambient temp.+5-60 4-60 Ambient temp.+5-60 4-60
Temp.accuracy ±0.1ºC
Temp. uniformity(ºC) ≤0.5(37ºC)
Temp. fluctuation(ºC) ≤0.2(37ºC)
Plate number 2
Size(mm) 700*560*1260 950*700*1260 1200*820*1560
Volume(L) 175 335 580
Power(w) 600 850 900 1150 1100 1400 1100 1400
Voltage AC220±10% 50-60HZ
Ambient temp.(ºC) 5-25
 
 
Horizontal type incubator shaker series:

Summary:

This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency.

Control feature:

Function of parameters memory and electricity incoming recovery when data lost because of power cut or system

Structure Feature:Sort: Microcomputer LCD type

Performance feature:

1 P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.

2 The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.

3 Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs. Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.

4 Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples. The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window. Use of microcomputer intelligent control system, powerful, strong anti-interference ability.

5 Can achieve the 1-24 time period of the day and night free combination of temperature and illumination parameters of ten sections of programming. Whole quiet design, electrostatic spray cabinet with tempered glass observation window, always observe the inside temperature and light conditions.

6 The top of the built-in light, special biological light source spectral characteristics, high strength, fever, particularly suitable for the experimental requirements


Parameters:
Model HNY-111A HNY-211A HNY-111B HNY-211B HNY-111C HNY-211C HNY-111F HNY-211F
Control mode P.I.D microcomputer processing chip
Convection mode Forced convection
Oscillation mode convolution Reciprocate
Display LCD display
USB data download system Yes
Kudan control system Yes
Lllumination 4  12000LX(max) No
Cyclotron frequency range 30-300rpm/min
Cyclotron frequency accuracy ±1
Shake plate shimmy range(mm) Ø26 0-50
Max configuration 100ml*66/250ml*45/
500ml*28
100ml*18/2000ml*11
250ml*45/500ml*28/1000ml*18/2000ml*11/5000ml*6 250ml*46/500ml*33/1000ml*18
Standard configuration  
500ml*28
2000ml*8 500ml*33
Pallet size(mm) 920*510 800*520
Timing(h) 0-999
Temp. range(ºC) Ambient temp.+5-60 4-60 Ambient temp.+5-60 4-60 Ambient temp.+5-60 4-60 Ambient temp.+5-60 4-60
Temp.accuracy ±0.1ºC
Temp. uniformity(ºC) ≤0.5(37ºC)
Temp. fluctuation(ºC) ≤0.2(37ºC)
Plate number 1
Size(mm) 1200*740*800 1200*740*1000 1200*740*800
Volume(L) 188 260 188
Power(w) 1100 1300 650 900 650 950 650 900
Voltage AC220±10% 50-60HZ
Ambient temp.(ºC) 5-25
 

Table-top type shaking incubator

Control Feature:

Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted.

Structure Feature:

Sort: Microcomputer LCD type 

Performance Feature:

1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.

2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations

3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.

4.Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs.

5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.

6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples.

7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.

 Parameters:

Model

HNY-209

HNY-100B

HNY-100D

HNY-200B

HNY-200D

Control mode

P.I.D microcomputer processing chip

Convection mode

Forced convection

Oscillation mode

convolution

Display

LED digital display

LCD display

USB data download system

No

Yes

Cyclotron frequency range

40-500rpm/min

30-600rpm/min

Cyclotron frequency accuracy

±1rpm

Shake plate shimmy range(mm)

Ø26

 

Ø26

 

Ø0-50

 

Ø26

 

Ø0-50

 

Max configuration

50ml*16/100ml*10/

250ml*8

100ml*23/250ml*12/500ml*9/1000ml*5

Standard configuration

50ml*4/100ml*3/

250ml*3

500ml*3  250ml*3

100ml*4   50ml*4

500ml*3  250ml*4

100ml*5   50ml*5

Pallet size(mm)

220*280

450*410

410*360

450*410

410*360

Timing(h)

0-166

0-999

Temp.range(°C)

10-60

Ambient temp.+5-60

4-60

Temp. accuracy(°C)

±0.1

Temp. uniformity(°C)

≤0.5(37°C)

Temp. fluctuation(°C)

≤0.2(37°C)

Pallet number

1

Size(mm)

550*510*440

740*710*510

Volume(L)

26

70

Power(w)

300

550

650

650

650

Voltage

AC220±10% 50-60HZ

Ambient temp.

5-25

Vertical and Table Type Shaking Incubator with Factory Price
 

Open type incubated shaker

Features:

1. Well constructed for long term operation.

2. Advance technology ensuring mechanical stability and reliability of operation.

3. Shaking mechanism is constructed with chromium alloy material and high quality cast iron.

4. Circuit breaker protect against excess current, power-off memory to return to original setting, soft start prevents splashing, auto cut-off if motor overheat.

5. Precision microprocessor control system, accuracy of speed ± 1rpm.

High Speed Lids Making Production Line

High Speed Lids Making Production Line,Aluminum Can Lid Manufacturing,Metal Cap Manufacturing Machine,Easy Open End Production Line

Zhoushan Jiaolong Import And Export Co., Ltd.   , https://www.jiaolongmachinery.com